TRIBOLOGIA

E-ISSN: 1732-422X
ICV: 100.00MNiSW: 70
TRIBOLOGIA
Published: 31-03-2026
Number of articles: 10
Scientific Editor: Jarosław Sęp
Other articles from this issue
31-03-2026 - Original article
Michał Wasilczuk, Michał Wodtke, Piotr Neubauer, Andreas Schubert

To ensure proper operation, the tilting pads of hydrodynamic thrust bearings must be supported in a way that allows the inclination of their sliding surface to be adjusted to the operating conditions, i.e., load and speed. The support position has a significant impact on operating parameters, as it influences the shape of the lubrication gap and, consequently, the operating parameters of the entire bearing. This paper presents the results of research on the influence of the support position of the tilting pads on the hydrodynamic operating parameters of a thrust bearing. Two cases of support location, most commonly met in practical applications, were analyzed: symmetrical support (used in bidirectional bearings) and off-set support (single-direction bearings). The paper presents theoretical analyses using advanced computational techniques. Analysis of the obtained results indicates different bearing operating parameters related to the shape of the lubrication gap and the associated temperature and pressure distributions in the bearing. The bearings also exhibited different friction losses depending on the position of the self-aligning support.

31-03-2026 - Original article
Magdalena Lemecha, Krzysztof Ligier, Dariusz Choszcz, Michał Janulin

This study analyzes the influence of FDM printing temperature on the wear properties of the PA-12 polyamide under dry friction conditions and in the presence of an abrasive slurry. Tests were carried out using the ball-cratering method at three extrusion temperatures (255 °C, 260 °C, and 265 °C). Under dry friction conditions, the highest wear rate was recorded for samples printed at 255 °C, while increasing the printing temperature to 260 °C and 265 °C progressively reduced the wear intensity. A similar decreasing trend was observed when friction occurred in the presence of an abrasive slurry, where higher printing temperatures led to significantly lower wear rates. This behavior can be attributed to improved interlayer bonding, enhanced structural cohesion, and reduced material porosity at elevated processing temperatures, which collectively increase the resistance of the material to both adhesive and abrasive wear mechanisms. Analysis of wear mechanisms revealed adhesion dominance under dry friction and abrasive wear in the presence of abrasive particles. The results confirm the significant impact of printing parameters on the tribological durability of FDM-manufactured components.

31-03-2026 - Original article
Tomasz Kiczek, Arkadiusz Stachowiak, Agata Bieńczak, Dariusz Ulbrich, Wiesław Zwierzycki, Paweł Woźniak, Perizat Baigozhina

The paper presents the results of tribocorrosion resistance tests of AISI 420 stainless steel in onion juice. The study constitutes one of the stages in selecting a suitable material for the production of onion-cutting knives. The main objective was to identify the optimal heat treatment conditions to minimize tribocorrosive wear. Tribocorrosion tests were carried out using a ball-on-plate configuration under a low normal load of 1.7 N, simulating the operating conditions of an onion-cutting knife. Two heat treatment variants of quenched AISI 420 steel were investigated: tempering at 400 °C (medium tempering) and tempering at 200 °C (low tempering). The results showed that the highest hardness (approximately 54 HRC) was obtained after low-temperature tempering. However, the samples tempered at 400 °C, which exhibited slightly lower hardness (about 51 HRC), demonstrated better tribocorrosion resistance in onion juice under low loads. In contrast, the harder samples (54 HRC) showed reduced corrosion resistance in onion juice and slightly higher susceptibility to cracking, resulting in lower tribocorrosion resistance compared with the samples tempered at 400 °C.

31-03-2026 - Original article
Mateusz Wójcicki, Andrzej Wieczorek

The article presents a methodology for testing the wear of chain links operating in a complex, degradation environment, taking into account the effects of abrasive, chemical, and dynamic factors. The design and construction of a test stand, enabling the recreation of real operating conditions with controlled selection of nominal and dynamic load parameters, mineral abrasive medium, and the presence of corrosive agents are described. The testing methodology, measurement procedures, and wear assessment methods are discussed. The results obtained during preliminary tests confirmed the suitability of the proposed methodology and test stand for analyzing the wear rate of conveyor chain joints under harsh operating conditions. The developed approach can be applied both in scientific research and in the designing process of more durable drive systems.

31-03-2026 - Original article
Bazyli Krupicz, Wojciech Tarasiuk, Paweł Krupicz

The aim of the work is to investigate the effect of initial deformation of 41Cr4 steel samples on the erosion wear rate under the influence of a stream of quartz sand particles. This chromium steel is widely applied in the construction of machines and devices. Erosion tests were performed on undeformed and deformed samples during uniaxial tension. The deformations of the samples were: 2.7%, 5.1%, and 7.3%. The angle between the particle stream axis and the sample was 25° and 90°, the stream speeds were 22.6 m/s, 34.1 m/s, and 57.1 m/s. The authors found that during permanent deformation of 41Cr4 steel samples, strain hardening occurred. It was manifested by an increase in hardness and a decrease in the specific work to break the sample. A linear relationship was found between the erosion rate and the specific work determined during static tension to break the tested sample.

31-03-2026 - Original article
Jakub Rutkowski, Janusz Musiał, Adam Troszyński, Serhiy Horiashchenko

This study investigated the influence of frequency, load, and test duration on the wear behavior of polymethyl methacrylate (PMMA) friction pairs under dry sliding conditions. Tribological tests were conducted using an MFT-5000 tribotester in a reciprocating pin-on-disc configuration simulating back-and-forth motion typical of tooth-grinding activity. Surface roughness parameters were evaluated using a Mahr profilometer with MarSurf XT20 software. The experimental program consisted of two test series designed to separately assess the influence of sliding frequency and normal load. In the first series, friction frequency was varied (1, 2, and 4 Hz) at a constant load of 70 N. In the second series, normal load was modified (50, 70, and 100 N) at a fixed frequency of 2 Hz. Each test lasted 15 minutes. The results demonstrated a clear, non-linear intensification of wear with increasing mechanical stress. The highest arithmetic mean surface height was observed at 100 N (Sa = 11.778 µm), whereas the lowest value occurred at 50 N (Sa = 0.288 µm), confirming that normal load is the dominant parameter governing wear regime transitions. Increasing sliding frequency also accelerated surface degradation, though to a lesser extent than load. The wear mechanism evolved from mild adhesive smoothing at 50 N to intermediate adhesive–microfatigue interaction at 70 N, and finally to severe viscoelastic–plastic deformation and material displacement at 100 N. These findings provide a practical basis for controlled acceleration of tribological testing while preserving representative degradation mechanisms relevant to dental PMMA applications.

31-03-2026 - Original article
Marek Szewczyk, Kacper Golba, Tomasz Trzepieciński, Krzysztof Szwajka, Joanna Zielińska-Szwajka, Jan Slota, Lubos Kascak

This article presents the results of a study examining the effect of contact pressure and sliding velocity on the coefficient of friction and the change in roughness of DC04 steel sheets used in the deep drawing process. The study was conducted using the strip drawing test method for three pressure and sliding velocity levels, both under dry friction conditions and with process oil lubrication. The coefficient of friction was determined based on the pulling and pressing forces as the average of three measurements, with a measurement uncertainty of no more than ±1%. The obtained coefficient of friction values ranged from 0.115 to 0.173. Lubrication efficiency depended on sliding velocity, ranging from 4.4% to 15.5% for 3 mm/s, 5.3% to 11.6% for 6 mm/s, and 8.4% to 20.2% for 9 mm/s. Analysis of variance and regression models were used to analyze the results, with coefficients of determination (R²) of 0.8300 for the friction coefficient and 0.5751 for the Sa parameter. All analyzed factors significantly influenced the friction coefficient, while the effect of sliding velocity on the Sa parameter proved to be statistically insignificant. It was found that with increasing sliding velocity, the friction coefficient decreased, while increasing contact pressure reduced the surface roughness of the samples after friction.

31-03-2026 - Original article
Łukasz Bojko

Acrylic polymers are used in patients with extensive tooth loss or edentulism due to local and general contraindications or financial restrictions regarding implant-based treatment. Given the transfer of functional loads and the need to assess the impact of the structure on the stomatognathic system, important criteria include the proper microstructure of the manufactured structures and the biotribological context. These determine the wear resistance in contact with opposing teeth. The aim of the study is to evaluate acrylic teeth used for removable dentures based on tribological tests and microscopic surface observations. The test samples were made from acrylic teeth supplied by various manufacturers. Tribological tests were performed on a Four-Ball Wear Tester Brown machine using a ball-three disc friction pair. Microscopic surface observations were performed on a Hitachi S3400N scanning electron microscope. The performed tests enabled the determination of the coefficients of friction and wear resistance resulting from the contact of acrylic and natural teeth in an artificial saliva environment, and the evaluation of the surface layer of acrylic teeth before and after the wear process.

31-03-2026 - Original article
Barbara Drenda, Marcin Szczęch, Wojciech Horak

Magnetorheological (MR) fluids are suspensions of ferromagnetic particles in a carrier liquid whose rheological properties change reversibly under the influence of a magnetic field. In practical applications, however, their usability also depends on zero-field rheology and tribological performance, which govern flow resistance, lubrication regimes, and wear. This study investigates the effect of fumed silica (FS) and SM-type carbonyl iron microparticles (CIP) on the rheological and tribological properties of MR fluids based on silicone oil. Rheological tests revealed that FS enhances the viscoelastic structure of the fluid, with further reinforcement observed upon CIP addition. Tribological measurements showed that while CIP improves wear resistance, it may also increase the coefficient of friction depending on sliding velocity and the lubrication regime. The most favorable performance was observed for the formulation containing 4% FS and 60% CIP, which exhibited the lowest and most stable friction values in the elastohydrodynamic (EHL) regime and minimal wear. These findings highlight the potential of FS and CIP as synergistic additives in MR fluid design, although further optimization is needed to reduce friction under operating conditions, including the use of anti-wear and friction-reducing additives.

31-03-2026 - Original article
Marcin Szczęch, Wojciech Horak, Tarasevych Yuliia

Magnetic fluids are materials consisting of magnetic particles suspended in a carrier liquid, whose rheological properties can be controlled by an external magnetic field. Depending on particle size, a distinction is made between ferrofluids (FF), which contain nanoparticles, and magnetorheological fluids (MRF), based on micrometer-sized particles. These materials find applications in devices such as dampers, clutches, and brakes with magnetic control, as well as in sensors, loudspeakers, seals, lubricants, and in medicine. The effectiveness of such fluids largely depends on the type of carrier liquid and the stability of the suspension. The study presents a preparation procedure for magnetic fluids based on the EFH1 ferrofluid, using various carrier liquids: hydrocarbon oil L-AN 15, turbine oil TU 32, ester oil POE, and silicone oil. The process included evaporating EFH1 liquid and mixing it with a carrier liquid. For the POE and silicone oils, the surfactant PB-139 was additionally applied. The results demonstrated the feasibility of preparing ferrofluids using the selected base liquids; however, a tendency for particle agglomeration was also observed, with aggregates reaching up to 58% of the total mass. The properties of the resulting ferrofluids were characterized by rheological measurements and particle size distribution analysis using the DLS technique.

 
31-03-2026-Original article - Pages: 83 - 91

STUDY OF THE FUMED SILICA IMPACT ON THE RHEOLOGICAL AND TRIBOLOGICAL PROPERTIES OF MR FLUIDS

  • 1. AGH University of Krakow, Faculty of Mechanical Engineering and Robotics
Published:31-03-2026

Language versions:
34
112
DOI:10.5604/01.3001.0055.7125
GICID:01.3001.0055.7125


 

Abstract

Magnetorheological (MR) fluids are suspensions of ferromagnetic particles in a carrier liquid whose rheological properties change reversibly under the influence of a magnetic field. In practical applications, however, their usability also depends on zero-field rheology and tribological performance, which govern flow resistance, lubrication regimes, and wear. This study investigates the effect of fumed silica (FS) and SM-type carbonyl iron microparticles (CIP) on the rheological and tribological properties of MR fluids based on silicone oil. Rheological tests revealed that FS enhances the viscoelastic structure of the fluid, with further reinforcement observed upon CIP addition. Tribological measurements showed that while CIP improves wear resistance, it may also increase the coefficient of friction depending on sliding velocity and the lubrication regime. The most favorable performance was observed for the formulation containing 4% FS and 60% CIP, which exhibited the lowest and most stable friction values in the elastohydrodynamic (EHL) regime and minimal wear. These findings highlight the potential of FS and CIP as synergistic additives in MR fluid design, although further optimization is needed to reduce friction under operating conditions, including the use of anti-wear and friction-reducing additives.

References:

1.
Ashtiani M, Hashemabadi SH, Ghaffari A. A reviewon the magnetorheological fluid preparation andstabilization. J Magn Magn Mater. 2015;374:716- 730 doi:10.1016/j.jmmm.2014.09.020.
2.
Vékás L. Ferrofluids and magnetorheological fluids.Adv Sci Technol. 2008;54:127-136.doi:10.4028/www.scientific.net/AST.54.127
3.
Stępień B, Horak W. Characterization ofmagnetorheological fluids produced using selectedcarbonyl iron powders. Tribologia. 2024;310(4):93- 101 doi:10.5604/01.3001.0054.9833
4.
Sharmili P, Rajesh S, Mahendran M, SaravanakumarS, Abirami G, Siavakami A, et al. Rheometric andstability analysis of additive infusedmagnetorheological fluids: a comparative study. EurPhys J E. 2023;46(6). doi:10.1140/epje/s10189-023-00262-1
5.
Bell RC, Miller ED, Karli JO, Vacreck AN,Zimmerman DT. Influence of particle shape on theproperties of magnetorheological fluids. Int J ModPhys B. 2007;21(28-29):5018-5025.doi:10.1142/S0217979207045979
6.
Cho MS, Cho YH, Choi HJ, Myung SJ. Synthesisand electrorheological characteristics of polyanilinecoated poly(methyl methacrylate) microsphere: sizeTRIBOLOGIA 1/2026 ISSN 1732-422X 91effect. Langmuir. 2003;19(14):5875-5881.doi:10.1021/la026969d
7.
Sun Y, Sang M, Xu Y, Zhang Z, Duan S, Wang Y,et al. Conductive magnetorheological fluid-basedflexible sensor with adjustable stiffness. Chem EngJ. 2024;489:151229. doi:10.1016/j.cej.2024.151229
8.
Milecki A, Hauke M. Application ofmagnetorheological fluid in industrial shockabsorbers. Mech Syst Signal Process. 2012;28:528- 541 doi:10.1016/j.ymssp.2011.11.008
9.
Wu J, Kong W, Liu Y. Structural development ofmagnetorheological fluid brakes/clutches: a review.J Magn Magn Mater. 2025;614:172697.doi:10.1016/j.jmmm.2024.172697
10.
Liu J, Li D, Cai J, Wang Z, Liu S. Advancedapplications of magnet in magnetic fluid seal: adevelopers’ perspective. J Magn Magn Mater.2023;579:170814.doi:10.1016/j.jmmm.2023.170814
11.
Kumar JS, Paul PS, Raghunathan G, Alex DG. Areview of challenges and solutions inmagnetorheological fluids. Int J Mech Mater Eng.2019;14:13. doi:10.1186/s40712-019-0109-2
12.
Dorosti AH, Ghatee M, Norouzi M. Preparation andcharacterization of water-based magnetorheologicalfluid using surfactant micelles. J Magn Magn Mater.2020;498:166193.doi:10.1016/j.jmmm.2019.166193
13.
Chauchan V, Kumar A, Sham R.Magnetorheological fluids: a comprehensive review.Manuf Rev. 2024;11(6).doi:10.1051/mfreview/2024005
14.
Kamble VG, Kolekar S, Madivalar C. Preparation ofmagnetorheological fluids using different carriers.Curr Res Nanotechnol. 2015;6(1):7-15.doi:10.3844/ajnsp.2015.7.15
15.
Wu X, Guo Y, Tian Z, Li H, Shi Z. High temperaturestable magnetorheological fluid with shear-thinningresistance. Materials. 2025;18(16):3840.doi:10.3390/ma18163840
16.
Luan X, Zhang E, Chen Y, Ma R, Gong K, Li W, etal. Chemically modified silicone oil with enhancedtribological properties. Lubricants.2022;10(12):364. doi:10.3390/lubricants10120364
17.
Gu G, Wu Z, Zhang Z, Qing F. Tribologicalproperties of fluorine-containing additives ofsilicone oil. Tribol Int. 2009;42(3):397-402.doi:10.1016/j.triboint.2008.07.012
18.
Wang Y, Zhang L, Liu A, Wu C. Tribologicalperformance of Mg alloy with nano additives insilicone oil lubricant. Tribol Int. 2023;188:108856.doi:10.1016/j.triboint.2023.108856
19.
Guo YQ, Xu ZD, Chen BB, Ran CS, Guo WY.Preparation and study of magnetorheological fluidsfor vibration control. Int J Acoust Vib.2017;22(2):194-200. doi:10.20855/ijav.2017.22.246
20.
Park BJ, Fang FF, Choi HJ. Magnetorheology:materials and application. Soft Matter. 2010;6:5246- 5253 doi:10.1039/C0SM00014K
21.
Xu J, Li J, Cao J. Effects of fumed silica onrheological properties of magnetorheological fluids.Colloid Polym Sci. 2018;296:1145-1156.doi:10.1007/s00396-018-4332-9
22.
Yu L, Chen F, Li H. Sedimentation stability ofsilicone oil-based magnetorheological fluids. FrontMater. 2024;11:1395507.doi:10.3389/fmats.2024.1395507
23.
Kciuk S, Kciuk M, Turczyn R. Magnetorheologicalcharacterisation of carbonyl iron suspension. JAchiev Mater Manuf Eng. 2009;33(2):135-141
24.
Cheng JZ, Liu K, Zhang ZC, Wei ZQ, Ma YH, LuSR. Effect of surfactants modified carbonyl iron onmagnetorheological fluids. J Supercond Nov Magn.2021;34:1177-1183. doi:10.1007/s10948-021-05813-1
25.
Lim ST, Cho MS, Jang IB, Choi HJ.Magnetorheological characterization of carbonyliron suspension stabilized by fumed silica. J MagnMagn Mater. 2004;282:170-173.doi:10.1016/j.jmmm.2004.04.040
26.
Aruna MN, Rahman MR, Joladarahi S, Kumar H,Devadas BP. Influence of fumed silica onmagnetorheological fluids sedimentation. J MagnMagn Mater. 2021;529:167910.doi:10.1016/j.jmmm.2021.167910
27.
Shahrivar K, Ortiz AL, de Vicente J. Tribologicalperformance of ferrofluids and magnetorheologicalfluids. Tribol Int. 2014;78:125-133.doi:10.1016/j.triboint.2014.05.008
28.
Song WL, Choi SB, Choi JY, Lee CH. Wear andfriction characteristics of magnetorheological fluid.Tribol Trans. 2011;54(4):616-624.doi:10.1080/10402004.2011.584365
29.
Bombard AJ, de Vicente J. Boundary lubrication ofmagnetorheological fluids in PTFE/steel contacts.Wear. 2012;296(1-2):484-490.doi:10.1016/j.wear.2012.08.012
30.
BASF. Carbonyl iron powder for diamond tool[Internet]. 2024 [cited 2025 Jul 28]. Available from:https://electronicselectric.basf.com/dam/jcr:84943579-9720-32b7-a94b-860a29c86d07/basf/electronicselectric/global/G-EDM-Electronic-Materials/metalsystems/carbonyl-iron-powder/2024-02-21%20CIPBrochure_DiamondTools.pdf